B–24, Appendix b – Hitachi SJ200 Series User Manual

Page 238

Advertising
background image

ModBus Data Listing

Appendix B

B–24

The table below lists the holding registers for the “F” Group Main Profile Parameters.

Note 1:

When the value is 10000 (100.0 seconds), a value in the second decimal place
is ignored.

Holding Registers, “F” Group Main Profile Parameters

Func.

Code

Name

R/W

Description

Network Data

Reg.

Range

Res.

F001

Output frequency
setting

R/W Standard default target

frequency that determines
constant motor speed,
range is 0.0 / start frequency
to 400 Hz

0023h

0 / (start

freq. x 10)

to 4000

0.1 Hz

F002

(high)

Acceleration (1) time
setting *1

R/W Standard default acceleration,

range is 0.01 to 3000 sec.

0024h

1 to

300000

0.01

sec

F002

(low)

R/W

0025h

F202

(high)

Acceleration (1) time
setting, 2nd motor *1

R/W Standard default acceleration,

2nd motor,
range is 0.01 to 3000 sec.

0026h

1 to

300000

0.01

sec

F202

(low)

R/W

0027h

F003

(high)

Deceleration (1) time
setting *1

R/W Standard default deceleration,

range is
0.01 to 3000 sec.

0028h

1 to

300000

0.01

sec

F003

(low)

R/W

0029h

F203

(high)

Deceleration (1) time
setting, 2nd motor *1

R/W Standard default deceleration,

2nd motor,
range is 0.01 to 3000 sec.

002Ah

1 to

300000

0.01

sec

F203

(low)

R/W

002Bh

F004

Keypad Run key routing R/W Two options; select codes:

00... Forward
01... Reverse

002Ch

0, 1