B–36, Appendix b – Hitachi SJ200 Series User Manual

Page 250

Advertising
background image

ModBus Data Listing

Appendix B

B–36

The following table lists the holding registers for the “C” Group Intelligent Input
Functions.

I

“C” Group Intelligent Terminal Functions

Func.

Code

Name

R/W

Description

Network Data

Reg.

Range

Res.

C001

Terminal [1] function

R/W

See

“Input Terminal Config-

uration” on page 3–41

00A7h

0, 1, 2, 3,
4, 5, 6, 7,

8, 9, 11,

12, 13,
15, 16,
18, 19,
20, 21,
22, 23,
24, 27,
28, 29,
31, 50,

51, 255

C002

Terminal [2] function

R/W

00A8h

C003

Terminal [3] function

R/W

00A9h

C004

Terminal [4] function

R/W

00AAh

C005

Terminal [5] function

R/W

00ABh

C006

Terminal [6] function

R/W

00ACh

C011

Terminal [1] active state R/W Select logic convention, two

option codes:
00... normally open [NO]
01... normally closed [NC]

00ADh

0, 1

C012

Terminal [2] active state R/W

00AEh

0, 1

C013

Terminal [3] active state R/W

00AFh

0, 1

C014

Terminal [4] active state R/W

00B0h

0, 1

C015

Terminal [5] active state R/W

00B1h

0, 1

C016

Terminal [6] active state R/W

00B2h

0, 1

C021

Terminal [11] function

R/W

See

“Output Terminal

Configuration” on page 3–

46

00B3h

0, 1, 2, 3,
4, 5, 6, 7,

8, 9

C022

Terminal [12] function

R/W

00B4h

C026

Alarm relay terminal
function

R/W

00B5h

C028

[AM] signal selection

R/W Two available functions:

00... Actual motor speed
01... Motor current

00B7h

0, 1

C031

Terminal [11] active
state

R/W Select logic convention, two

option codes:
00... normally open (NO)
01... normally closed (NC)

00B8h

0, 1

C032

Terminal [12] active
state

R/W Select logic convention, two

option codes:
00... normally open (NO)
01... normally closed (NC)

00B9h

0, 1

C036

Alarm relay active state

R/W Select logic convention, two

option codes:
00... normally open (NO)
01... normally closed (NC)

00BAh

0, 1

Advertising