NOTE: For A095 and A096 (and for 2nd motor settings), if you set a very rapid Acc1 or
Dec1 time (less than 1.0 second), the inverter may not be able to change rates to Acc2 or
Dec2 before reaching the target frequency. In that case, the inverter decreases the rate of
Acc1 or Dec1 in order to achieve the second ramp to the target frequency.

A095 Acc1 to Acc2 frequency

transition point

Output frequency at which
Accel1 switches to Accel2,
range is 0.0 to 400.0 Hz

0.0

0.0

Hz

ACC CHfr0000.0Hz

A295 Acc1 to Acc2 frequency

transition point, 2nd
motor

Output frequency at which
Accel1 switches to Accel2,
range is 0.0 to 400.0 Hz

0.0

0.0

Hz

2ACCCHfr0000.0Hz

A096 Dec1 to Dec2 frequency

transition point

Output frequency at which
Decel1 switches to Decel2,
range is 0.0 to 400.0 Hz

0.0

0.0

Hz

DEC CHfr0000.0Hz

A296 Dec1 to Dec2 frequency

transition point, 2nd
motor

Output frequency at which
Decel1 switches to Decel2,
range is 0.0 to 400.0 Hz

0.0

0.0

Hz

2DECCHfr0000.0Hz