B–27, Appendix b – Hitachi SJ200 Series User Manual

Page 241

Advertising
background image

SJ200 Inverter

Appendix B

B–27

A042

Manual torque boost
value

R/W Can boost starting torque

between 0 and 20% above
normal V/f curve,
range is 0.0 to 20.0%

004Fh

0 to 200

0.1 %

A242

Manual torque boost
value, 2nd motor

R/W

0050h

A043

Manual torque boost
frequency adjustment

R/W Sets the frequency of the V/f

breakpoint A in graph (top of
previous page) for torque
boost, range is 0.0 to 50.0%

0051h

0 to 500

0.1 %

A243

Manual torque boost
frequency adjustment,
2nd motor

R/W

0052h

A044

V/f characteristic curve
selection

R/W Two available V/f curves;

three select codes:
00... Constant torque
01... Reduced torque
02... Intelligent sensorless
vector control

0053h

0, 1, 2

A244

V/f characteristic curve
selection, 2nd motor

R/W

0054h

A045

V/f gain setting

R/W Sets voltage gain of the

inverter, range is 20. to 100.%

0055h

20 to 100

1 %

A046

Automatic torque boost
voltage gain

R/W Sets torque boost voltage gain

of the inverter,
range is 0 to 255

0056h

0 to 255

A246

Automatic torque boost
voltage gain, 2nd motor

R/W

0057h

A047

Automatic torque boost
slip gain

R/W Sets torque boost slip gain of

the inverter,
range is 0 to 255

0058h

0 to 255

A247

Automatic torque boost
slip gain, 2nd motor

R/W

0059h

A051

DC braking enable

R/W Two options; select codes:

00... Disable
01... Enable

005Ch

0, 1

A052

DC braking frequency
setting

R/W The frequency at which DC

braking begins,
range is from the start
frequency (B082) to 60 Hz

005Dh

(B082 x

10) to 600

0.1 Hz

A053

DC braking wait time

R/W The delay from the end of

controlled deceleration to start
of DC braking (motor free runs
until DC braking begins),
range is 0.0 to 5.0 sec.

005Eh

0, 1

A054

DC braking force for
deceleration

R/W Level of DC braking force,

settable from 0 to 100%

005Fh

0 to 100

1 %

A055

DC braking time for
deceleration

R/W Sets the duration for DC

braking, range is 0.0 to 60.0
seconds

0060h

0 to 600

0.1 sec

Holding Registers for “A” Group Standard Functions

Func.

Code

Name

R/W

Description

Network Data

Reg.

Range

Res.

Advertising