SJ200 Inverter

Appendix C

C–9

Intelligent Terminal Functions

“C” Group Parameters

Default Setting

User

Setting

Func.

Code

Name

-FEF

(EU)

-FU

(USA)

C001

Terminal [1] function

00

00

C002

Terminal [2] function

01

01

C003

Terminal [3] function

02

16

C004

Terminal [4] function

03

13

C005

Terminal [5] function

18

09

C006

Terminal [6] function

09

18

C011

Terminal [1] active state

00

00

C012

Terminal [2] active state

00

00

C013

Terminal [3] active state

00

00

C014

Terminal [4] active state

00

01

C015

Terminal [5] active state

00

00

C016

Terminal [6] active state

00

00

C021

Terminal [11] function

01

01

C022

Terminal [12] function

00

00

C026

Alarm relay terminal function

05

05

C028

[AM] signal selection

00

00

C031

Terminal [11] active state

00

00

C032

Terminal [12] active state

00

00

C036

Alarm relay active state

01

01

C041

Overload level setting

Inverter

rated

current

Inverter

rated

current

C042

Frequency arrival setting for
acceleration

0.0

0.0

C043

Arrival frequency setting for
deceleration

0.0

0.0

C044

PID deviation level setting

3.0

3.0

C052

PID FBV function high limit

100.0

100.0

C053

PID FBV function low limit

0.0

0.0

C071

Communication speed selection

06

04

C072

Node allocation

1.

1.

C074

Communication parity selection

00

00

Advertising