“C” Group: Intelligent Terminal Functions

Configur

ing

Dr

iv

e P

a

ra

m

e

ters

3–52

Miscellaneous Functions

The following table contains miscellaneous functions not in other function groups.

“C” Function

Run

Mode

Edit

Defaults

Func.

Code

Name /

SRW Display

Description

–FEF

(EU)

–FU

(USA)

Units

C091 Debug mode enable

Displays debug parameters.
Two option codes:
00... Disable
01... Enable

00

00

DBG Slct OFF

C101 Up/Down memory

mode selection

Controls speed setpoint for the
inverter after power cycle. Two
option codes:
00... Clear last frequency
(return to default frequency
F001)
01... Keep last frequency
adjusted by UP/DWN

00

00

UP/DWN NO-STR

C102 Reset selection

Determines response to Reset
input [RST].
Three option codes:
00... Cancel trip state at input
signal ON transition, stops
inverter if in Run Mode
01... Cancel trip state at signal
OFF transition, stops inverter if
in Run Mode
02... Cancel trip state at input
signal ON transition, no effect
if in Run Mode

00

00

RS Slct ON