Oper ations and monitor ing – Hitachi SJ200 Series User Manual

Page 184

Advertising
background image

SJ200 Inverter

Oper

ations

and Monitor

ing

4–57

Having two motor profiles lets you store two “personalities” for motors in one inverter’s
memory. The inverter allows the final selection between the two motor types to be made
in the field through the use of an intelligent input terminal function [SET]. This provides
an extra level of flexibility needed in particular situations. See the following table.

Parameters for the second motor have a function code of the form x2xx. They appear
immediately after the first motor’s parameter in the menu listing order. The following
table lists the parameters that have the second parameter register for programming.

Function Name

Parameter Codes

1st motor

2nd motor

Multi-speed frequency setting

A020

A220

Acceleration (1) time setting

F002

F202

Deceleration (1) time setting

F003

F203

Acceleration (2) time setting

A092

A292

Deceleration (2) time setting

A093

A293

Select method to use Acc2/Dec2

A094

A294

Acc1 to Acc2 frequency transition point

A095

A295

Dec1 to Dec2 frequency transition point

A096

A296

Level of electronic thermal setting

B012

B212

Electronic thermal characteristic

B013

B213

Manual torque boost value

A042

A242

Manual torque boost frequency adjustment

A043

A243

V/f characteristic curve selection

A044

A244

iSLV voltage gain

A046

A246

iSLV slip compensation

A047

A247

Base frequency setting

A003

A203

Maximum frequency setting

A004

A204

Frequency upper limit setting

A061

A261

Frequency lower limit setting

A062

A262

Motor capacity

H003

H203

Motor poles setting

H004

H204

Motor stabilization constant

H006

H206

Motor voltage select

H007

H207