“D” Group: Monitoring Functions

Configur

ing

Dr

iv

e P

a

ra

m

e

ters

3–6

“D” Group: Monitoring Functions

You can access important system parameter values with the “D” Group monitoring
functions, whether the inverter is in Run Mode or Stop Mode. After selecting the
function code number for the parameter you want to monitor, press the Function key
once to show the value on the display. In functions D005 and D006, the intelligent termi-
nals use individual segments of the display to show ON/OFF status.

If the inverter display is set to monitor a parameter and powerdown occurs, the inverter
stores the present monitor function setting. For your convenience, the display automati-
cally returns to the previously monitored parameter upon the next powerup.

“D” Function

Run

Mode

Edit

Units

Func.

Code

Name /

SRW Display

Description

D001 Output frequency

monitor

Real-time display of output
frequency to motor, from
0.0 to 400.0 Hz

Hz

FM 0000.00Hz

D002 Output current monitor

Filtered display of output current
to motor (100 ms internal filter
time constant), range is
0 to 200% of inverter rated current

A

Iout 0000.0A

D003 Rotation direction

monitor

Three different indications:
“F”..... Forward
“o” .. Stop
“r”..... Reverse

Dir STOP

D004 Process variable (PV),

PID feedback monitor

Displays the scaled PID process
variable (feedback) value (A075 is
scale factor),
0.00 to 99.99, 100.0 to 999.9,
1000. to 9999., 1000 to 999,
and 10000 to 99900

% times

constant

FB 00000.00%

D005 Intelligent input

terminal status

Displays the state of the intelligent
input terminals:

IN-TM LLLLLL

D006 Intelligent output

terminal status

Displays the state of the intelligent
output terminals:

OUT-TM LLL

ON

OFF

1

2

3

4

5

6
Terminal numbers

ON

OFF

11

12

Terminal numbers

AL