Hitachi SJ200 Series User Manual

Page 93

Advertising
background image

SJ200 Inverter

Conf

igur

ing

Dr
iv

e P

a

ra

m

e

ters

3–21

Jump Frequencies – Some motors or machines exhibit resonances at particular
speed(s), which can be destructive for prolonged running at those speeds. The inverter
has up to three jump frequencies as shown in the graph. The hysteresis around the jump
frequencies causes the inverter output to skip around the sensitive frequency values.

Jump frequencies

Output

frequency

Frequency command

Hysteresis values

0

A067

A065

A063

A064

A064

A066

A066

A068

A068

“A” Function

Run

Mode

Edit

Defaults

Func.

Code

Name /

SRW Display

Description

–FEF

(EU)

–FU

(USA)

Units

A063,
A065,

A067

Jump (center) frequency
setting

Up to 3 output frequencies can
be defined for the output to
jump past to avoid motor
resonances (center frequency)
Range is 0.0 to 400.0 Hz

0.0
0.0
0.0

0.0
0.0
0.0

Hz

JUMP F1 0000.0Hz
JUMP F2 0000.0Hz
JUMP F3 0000.0Hz

A064,
A066,

A068

Jump (hysteresis)
frequency width setting

Defines the distance from the
center frequency at which the
jump around occurs
Range is 0.0 to 10.0 Hz

0.5
0.5
0.5

0.5
0.5
0.5

Hz

JUMP W1 0000.5Hz
JUMP W2 0000.5Hz
JUMP W3 0000.5Hz