Making settings for sample (sample parameters), 150 editing a sample – Roland Fantom-X7 User Manual

Page 150

Advertising
background image

150

Editing a Sample

Here you can make various settings for the sample.

1.

Press [SAMPLE LIST] and select the sample that you want
to edit (p. 146).

2.

Press [SAMPLE EDIT] to access the Sample Edit screen,
and press [F2 (Sample Param)].

fig.15-004_50

3.

Press

or

to select a parameter.

4.

Use VALUE dial or [INC], [DEC] to edit the value.

Loop Mode

Specifies how the sample will be played.

Value

FWD (Forward)

After the Sample played back from the Start point to the End
point, it will then be repeatedly played back in the forward
direction, from the Loop Start point to the End point.

fig.15-005

ONE-SHOT

The sample will be played back only once, from the Start point
to the End point.

fig.15-006

REV (Reverse)

When the sample has been played back from the End point to
the Start point, it will be repeatedly played back in the reverse
direction, from the Loop Start point to the Start point.

fig.15-007

REV-ONE (Reverse One-shot)

The sample will be played back only once from the End point to
the Start point in the reverse direction.

fig.15-008

Loop Tune

Specifies the pitch of the loop region.

Value:

-50– +50

*

Make fine adjustments in one-cent (1/100 semitone) increments.

Original Key

Note number that will play the sample at the pitch at which it
was sampled.

Value:

0 (C-1)–127 (G9)

BPM (TEMPO)

Specifies the original tempo of the sample.

Value:

5.00–300.00

*

In order to synchronize the tempo, Wave Temp Sync (p. 63) must be
turned on.

*

When setting the BPM (tempo) value, you can hold down [SHIFT]
and turn the VALUE dial, or use [INC] [DEC] to adjust the value to
the right of the decimal point.

Time Stretch Type

Specifies how the tempo will be synchronized. Decreasing this
value will optimize the sound for more rapid phrases, and
increasing this value will optimize the sound for slower
phrases.

Value:

TYPE01–TYPE10

Start Fine

Fine adjustment of the Start point.

Value:

0–255

Loop Start Fine

Fine adjustment of the Loop Start point.

Value:

0–255

Loop End Fine

Fine adjustment of the End point.

Value:

0–255

*

By pressing [F7 (Reset Grid)] you can reassign the sample grid
according to the specified start point and BPM. To execute, press [F8
(Exec)].

5.

Press [EXIT] when you are finished.

Making Settings for Sample

(Sample Parameters)

Start P.

Loop
Start P.

End P.

Start P.

Loop
Start P.

End P.

Start P.

Loop
Start P.

End P.

Start P.

Loop
Start P.

End P.

Fantom-X678_r_e.book 150 ページ 2005年5月12日 木曜日 午後4時40分