Modulating sounds (lfo), P. 74, Lfo 1/2 – Roland Fantom-X7 User Manual

Page 74: 74 creating a patch

Advertising
background image

74

Creating a Patch

Tone Out Level

Set the level of the signal that is sent to the output destination
specified by Tone Output Assign.

Value:

0–127

Tone Chorus Send (Send Level (Output=MFX))

Specifies the level of the signal sent to the chorus for each tone if the
tone is sent through MFX.

Value:

0–127

Tone Reverb Send (Send Level (Output=MFX))

Specifies the level of the signal sent to the reverb for each tone if the
tone is sent through MFX.

Value:

0–127

Tone Chorus Send (Send Level (Output=non

MFX))

Sets the level of the signal sent to chorus for each tone if the tone is
not sent through MFX.

Value:

0–127

Tone Reverb Send (Send Level (Output=non

MFX))

Sets the level of the signal sent to reverb for each tone if the tone is
not sent through MFX.

Value:

0–127

fig.06-042_50

For details on these settings, refer to

“How to Make Patch

Settings”

(p. 56).

An LFO (Low Frequency Oscillator) causes change over a cycle
in a sound. Each tone has two LFOs (LFO1/LFO2), and these
can be used to cyclically change the pitch, cutoff frequency and
volume to create modulation-type effects such as vibrato, wah
and tremolo. Both LFOs have the same parameters so only one
explanation is needed.

LFO 1/2

Waveform (LFO1/LFO2 Waveform)

Selects the waveform of the LFO.

Value

SIN:

Sine wave

TRI:

Triangle wave

SAW-U:

Sawtooth wave

SAW-D:

Sawtooth wave (negative polarity)

SQR:

Square wave

RND:

Random wave

BND-U:

Once the attack of the waveform output by the LFO
is allowed to develop in standard fashion, the
waveform then continues without further change.

BND-D:

Once the decay of the waveform output by the LFO
is allowed to develop in standard fashion, the
waveform then continues without further change.

TRP:

Trapezoidal wave

S&H:

Sample & Hold wave (one time per cycle, LFO value
is changed)

CHAOS:

Chaos wave

VSIN:

Modified sine wave. The amplitude of a sine wave is
randomly varied once each cycle.

STEP:

A waveform generated by the data specified by LFO
Step 1–16. This produces stepped change with a
fixed pattern similar to a step modulator.

If you set this to “BND-U” or “BND-D,” you must turn the Key
Trigger parameter to “ON.” If this is “OFF,” it will have no
effect.

LFO Rate (LFO1/LFO2 Rate)

Adjusts the modulation rate, or speed, of the LFO.

Value:

0–127, Note

LFO Rate sets the beat length for the synchronized tempo is
synchronized with the tempo set in a sequencer.

(Example)

For a tempo of 120 (120 quarter notes occur in 1 minute (60 seconds))

This setting will be ignored if the Waveform parameter is set to
“CHAOS.”

Modulating Sounds (LFO)

1

2

3

4

Setting

LFO Rate

(half note)

1 second (60 / 60 =1 (second))

(quarter note)

0.5 seconds (60 / 120= 0.5 (seconds))

(eighth note)

0.25 seconds (60 / 240= 0.25 (seconds))

1

Fantom-X678_r_e.book 74 ページ 2005年5月12日 木曜日 午後4時40分