304 midi implementation, Data transmission, Channel voice messages – Roland Fantom-X7 User Manual

Page 304

Advertising
background image

304

MIDI Implementation

Data set 1

DT1

Status

Data byte

Status

F0H

41H, dev, 00H, 6BH, 12H, aaH, bbH,

F7H

ccH, ddH, eeH, ... ffH, sum

Byte

Explanation

F0H

Exclusive status

41H

ID number (Roland)

dev

Device ID (dev: 00H - 1FH, 7FH)

00H

Model ID #1 (Fantom-X6/X7/X8)

6BH

Model ID #2 (Fantom-X6/X7/X8)

12H

Command ID (DT1)

aaH

Address MSB: upper byte of the starting address of the data to be

sent

bbH

Address:

upper middle byte of the starting address of the data
to be sent

ccH

Address:

lower middle byte of the starting address of the data
to be sent

ddH

Address LSB: lower byte of the starting address of the data to be

sent.

eeH

Data:

the actual data to be sent. Multiple bytes of data are
transmitted in order starting from the address.

:

:

ffH

Data

sum

Checksum

F7H

EOX (End Of Exclusive)

*

The amount of data that can be transmitted at one time depends on the type of data, and
data will be transmitted from the specified starting address and size. Refer to the address
and size given in

Parameter Address Map

(P.311).

*

Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each
packet will be sent at an interval of about 20 ms.

*

Regarding the checksum, please refer to P.329.

*

Not received when the Receive Exclusive parameter (SYSTEM/MIDI) is OFF.

Status

Data byte

Status

F0H

41H, dev, 42H, 12H, aaH, bbH, ccH,

F7H

ddH, ... eeH, sum

Byte

Explanation

F0H

Exclusive status

41H

ID number (Roland)

dev

Device ID (dev: 10H - 1FH, 7FH)

42H

Model ID (GS)

12H

Command ID (DT1)

aaH

Address MSB: upper byte of the starting address of the transmitted

data

bbH

Address:

middle byte of the starting address of the transmitted
data

ccH

Address LSB:

lower byte of the starting address of the transmitted
data

ddH

Data:

the actual data to be transmitted. Multiple bytes of
data are transmitted starting from the address.

:

:

eeH

Data

sum

Checksum

F7H

EOX (End Of Exclusive)

*

The amount of data that can be transmitted at one time depends on the type of data, and
data will be transmitted from the specified starting address and size. Refer to the address
and size given in

Parameter Address Map

(P.311).

*

Data larger than 256 bytes will be divided into packets of 256 bytes or less, and each
packet will be sent at an interval of about 20 ms.

*

Regarding the checksum, please refer to P.329.

*

Not received when the Receive Exclusive parameter (SYSTEM/MIDI) is OFF.

2. Data Transmission

Channel Voice Messages

Note off

Status

2nd byte

3rd byte

8nH

kkH

vvH

n = MIDI channel number:

0H - FH (ch.1 - 16)

kk = note number:

00H - 7FH (0 - 127)

vv = note off velocity:

00H - 7FH (0 - 127)

Note on

Status

2nd byte

3rd byte

9nH

kkH

vvH

n = MIDI channel number:

0H - FH (ch.1 - 16)

kk = note number:

00H - 7FH (0 - 127)

vv = note on velocity:

01H - 7FH (1 - 127)

Polyphonic Key Pressure

Status

2nd byte

3rd byte

AnH

kkH

vvH

n = MIDI channel number:

0H - FH (ch.1 - 16)

kk = note number:

00H - 7FH (0 - 127)

vv = Polyphonic Key Pressure:

00H - 7FH (0 - 127)

Control Change

*

By selecting a controller number that corresponds to the setting of parameters of
controllers (REALTIME CONTROL knob, and so on), the Fantom-X can transmit any
control change message.

Bank Select (Controller number 0, 32)

Status

2nd byte

3rd byte

BnH

00H

mmH

BnH

20H

llH

n = MIDI channel number:

0H - FH (ch.1 - 16)

mm, ll = Bank number:

00 00H - 7F 7FH (bank.1 - bank.16384)

*

These messages are transmitted when Patch, Rhythm Set or Performance is selected. But
not transmitted when Transmit Program Change or Transmit Bank Select parameter
(SYSTEM/MIDI) is OFF.

*

In Performance mode, these messages are not transmitted when External Bank Select
MSB or External PC Number parameter (PERFORMANCE/PART) is OFF.

*

Although with the Fantom-X you can select the Bank Select messages to be transmitted,
be sure to refer to the Program Change Map on P.330 for the Bank Select messages
transmitted when the Fantom-X is select a Patch, Rhythm Set or Performance.

*

The Bank Select Numbers corresponding to SRX series should be referred to the SRX
series owner’s manual.

Modulation (Controller number 1)

Status

2nd byte

3rd byte

BnH

01H

vvH

n = MIDI channel number:

0H - FH (ch.1 - 16)

vv = Modulation depth:

00H - 7FH (0 - 127)

Breath type (Controller number 2)

Status

2nd byte

3rd byte

BnH

02H

vvH

n = MIDI channel number:

0H - FH (ch.1 - 16)

vv = Control value:

00H - 7FH (0 - 127)

Portamento Time (Controller number 5)

Status

2nd byte

3rd byte

BnH

05H

vvH

n = MIDI channel number:

0H - FH (ch.1 - 16)

vv = Portamento Time:

00H - 7FH (0 - 127)

Data Entry (Controller number 6, 38)

Status

2nd byte

3rd byte

BnH

06H

mmH

BnH

26H

llH

n = MIDI channel number: 0H - FH (ch.1 - 16)
mm, ll = the value of the parameter specified by RPN/NRPN
mm = MSB, ll = LSB

Fantom-X678_r_e.book 304 ページ 2005年5月12日 木曜日 午後4時40分