Data lines to define mass flow rates – ABAQUS Volume II: I–Z User Manual

Page 134

Advertising
background image

*MASS FLOW RATE

Data lines to define mass flow rates:

First line:

1. Node number or node set label.

2. Mass flow rate per unit area in the x-direction (units of ML

−2

T

−1

) or total mass flow rate in the

cross-section (units of MT

−1

) for one-dimensional elements.

3. Mass flow rate per unit area in the y-direction (not needed for nodes associated with one-

dimensional elements).

4. Mass flow rate per unit area in the z-direction (not needed for nodes associated with one-

dimensional elements).

Repeat this data line as often as necessary to define mass flow rates at different nodes.

Data lines to define mass flow rates using user subroutine

UMASFL:

First line:

1. Node set or node number.

Repeat this data line as often as necessary.

UMASFL will be called for each node listed.