Optional parameters – ABAQUS Volume II: I–Z User Manual

Page 323

Advertising
background image

*RADIATION PRINT

17.4

*RADIATION PRINT:

Define print requests for cavity radiation heat transfer.

This option is used to print tabular output of cavity radiation variables (radiation fluxes, viewfactor totals, and
facet temperatures).

Product:

ABAQUS/Standard

Type:

History data

Level:

Step

References:

“Cavity radiation,” Section 32.1.1 of the ABAQUS Analysis User’s Manual

“Output,” Section 4.1.1 of the ABAQUS Analysis User’s Manual

Optional, mutually exclusive parameters (if not specified, output will be provided for all cavities
in the model):

CAVITY

Set this parameter equal to the name of the cavity for which this output request is being made.

ELSET

Set this parameter equal to the name of the element set for which this output request is being made.

SURFACE

Set this parameter equal to the name of the surface for which this output request is being made.

Optional parameters:

FREQUENCY

Set this parameter equal to the output frequency, in increments. The output will always be printed
at the last increment of each step unless FREQUENCY=0. The default is FREQUENCY=1. Set
FREQUENCY=0 to suppress the output.

SUMMARY

Set SUMMARY=YES (default) to obtain a summary of the maximum and minimum values in each
column of the table and their locations.

Set SUMMARY=NO to suppress this summary.

TOTALS

Set TOTALS=YES to print the total of each column in the table. This is useful, for example, to sum
radiation fluxes over all facets composing a radiation surface. The default is TOTALS=NO.

17.4–1

ABAQUS Version 6.1

Module: ID:

Printed on:

Advertising