*PHYSICAL CONSTANTS

16.7

*PHYSICAL CONSTANTS:

Specify physical constants.

This option is used to define physical constants necessary for an analysis; since ABAQUS has no built-in
units, no default values are provided. If a physical constant required for the analysis is not given, ABAQUS
will issue a fatal error message. The units used for the constants must be consistent with the remaining input
data.

Products:

ABAQUS/Standard

ABAQUS/Explicit

Type:

Model data

Level:

Model

References:

“Uncoupled heat transfer analysis,” Section 6.5.2 of the ABAQUS Analysis User’s Manual

“Mass diffusion analysis,” Section 6.8.1 of the ABAQUS Analysis User’s Manual

“Modeling fluid-filled cavities,” Section 11.5.1 of the ABAQUS Analysis User’s Manual

“Rate-dependent plasticity: creep and swelling,” Section 18.2.4 of the ABAQUS Analysis User’s Manual

“Hydrostatic fluid models,” Section 20.4.1 of the ABAQUS Analysis User’s Manual

“Diffusivity,” Section 20.5.1 of the ABAQUS Analysis User’s Manual

“Solubility,” Section 20.5.2 of the ABAQUS Analysis User’s Manual

“Thermal contact properties,” Section 30.2.1 of the ABAQUS Analysis User’s Manual

“Cavity radiation,” Section 32.1.1 of the ABAQUS Analysis User’s Manual

Optional parameters:

ABSOLUTE ZERO

Set this parameter equal to the absolute zero on the temperature scale chosen. For example, if the
analysis uses temperature in degrees Celsius, set ABSOLUTE ZERO=−273.15.

STEFAN BOLTZMANN

Set this parameter equal to the Stefan Boltzmann constant.

For example, STEFAN

BOLTZMANN=5.669 × 10

−8

Joule per sec m

2

Kelvin

4

in SI units.

UNIVERSAL GAS CONSTANT

Set this parameter equal to the universal gas constant.

For example, UNIVERSAL GAS

CONSTANT=8.31434 Joule per mole Kelvin in SI units.