*TEMPERATURE

19.1

*TEMPERATURE:

Specify temperature as a predefined field.

This option is used to specify temperature as a predefined field during an analysis.

To use this option in a restart analysis of ABAQUS/Standard, either *TEMPERATURE or *INITIAL

CONDITIONS, TYPE=TEMPERATURE must have been specified in the original analysis.

Products:

ABAQUS/Standard

ABAQUS/Explicit

Type:

History data

Level:

Step

References:

“Predefined fields,” Section 27.6.1 of the ABAQUS Analysis User’s Manual

“UTEMP,” Section 1.1.41 of the ABAQUS User Subroutines Reference Manual

Optional parameters for using the data line format:

AMPLITUDE

Set this parameter equal to the name of the amplitude curve that gives the time variation of the
temperature throughout the step (see “Amplitude curves,” Section 27.1.2 of the ABAQUS Analysis
User’s Manual).

If this parameter is omitted in an ABAQUS/Standard analysis, the reference magnitude is

applied immediately at the beginning of the step or linearly over the step, depending on the value
assigned to the AMPLITUDE parameter on the *STEP option (see “Procedures: overview,”
Section 6.1.1 of the ABAQUS Analysis User’s Manual).

If this parameter is omitted in an

ABAQUS/Explicit analysis, a linear interpolation is done over the step.

INPUT

Set this parameter equal to the name of the alternate input file containing the data lines for this
option. See “Input syntax rules,” Section 1.2.1 of the ABAQUS Analysis User’s Manual, for the
syntax of such file names. If this parameter is omitted, it is assumed that the data follow the keyword
line.

OP

Set OP=MOD (default) for existing *TEMPERATURE values to remain, with this option modifying
existing temperatures or defining additional temperatures.

Set OP=NEW if all existing *TEMPERATURE values should be removed. New temperatures

can be defined.

A temperature that is removed via OP=NEW is reset to the value given on the *INITIAL

CONDITIONS option or to zero if no initial temperature was defined. If temperatures are being
returned to their initial condition values, the AMPLITUDE parameter described above does not

19.1–1