Optional parameter – ABAQUS Volume II: I–Z User Manual

Page 577

Advertising
background image

*TRS

19.14

*TRS:

Used to define temperature-time shift for time history viscoelastic analysis.

This option can be used only in conjunction with the *VISCOELASTIC option.

In an ABAQUS/Standard analysis, viscoelasticity must be defined in the time domain by using the

*VISCOELASTIC option with the TIME parameter.

Products:

ABAQUS/Standard

ABAQUS/Explicit

Type:

Model data

Level:

Model

References:

“Time domain viscoelasticity,” Section 17.7.1 of the ABAQUS Analysis User’s Manual

“UTRS,” Section 1.1.43 of the ABAQUS User Subroutines Reference Manual

*VISCOELASTIC

Optional parameter:

DEFINITION

This parameter applies only to ABAQUS/Standard analyses. In an ABAQUS/Explicit analysis the
Williams-Landell-Ferry approximation is the only available choice.

Set DEFINITION=WLF (default) to define the shift function by the Williams-Landell-Ferry

approximation.

Set DEFINITION=USER to define the shift function in user subroutine UTRS.

Data line to define the shift function by the Williams-Landell-Ferry approximation:

First (and only) line:

1. Reference temperature,

.

2. Calibration constant,

.

3. Calibration constant,

.

To define a shift function not approximated by the WLF function:

No data lines are used with this option when DEFINITION=USER is specified. Instead, user
subroutine UTRS must be used to define the shift function.

19.14–1

ABAQUS Version 6.1

Module: ID: