*SRADIATE

18.30

*SRADIATE:

Specify surface radiation conditions in heat transfer analysis.

This option is used to apply surface radiation boundary conditions between a nonconcave surface and a
nonreflecting environment in fully coupled thermal-stress analysis. In ABAQUS/Standard it is also used
for heat transfer and coupled thermal-electrical analyses.

It must be used in conjunction with the *PHYSICAL CONSTANTS option, which is used to define the

Stefan-Boltzmann constant.

Products:

ABAQUS/Standard

ABAQUS/Explicit

Type:

History data

Level:

Step

Reference:

“Thermal loads,” Section 27.4.4 of the ABAQUS Analysis User’s Manual

Optional parameters:

AMPLITUDE

Set this parameter equal to the name of the *AMPLITUDE option that gives the variation of the
ambient temperature with time.

If this parameter is omitted in an ABAQUS/Standard analysis, the reference magnitude is

applied immediately at the beginning of the step or linearly over the step, depending on the value
assigned to the AMPLITUDE parameter on the *STEP option (see “Procedures: overview,”
Section 6.1.1 of the ABAQUS Analysis User’s Manual).

If this parameter is omitted in an

ABAQUS/Explicit analysis, the reference magnitude is applied immediately at the beginning of
the step.

OP

Set OP=MOD (default) for existing *SRADIATE definitions to remain, with this option modifying
existing radiation conditions or defining additional radiation conditions.

Set OP=NEW if all existing *SRADIATE definitions applied to the model should be removed.

Data lines to define surface radiation conditions:

First line:

1. Surface name.

2. Radiation type label R.

3. Reference ambient temperature value,

. (Units of .)