*IMPEDANCE PROPERTY

Data lines to define an impedance using DATA=ADMITTANCE (default):

First line:

1.

, the proportionality factor between pressure and displacement of the surface in the normal

direction. This quantity is the imaginary part of the complex admittance, divided by the angular
frequency; see “Acoustic loads,” Section 27.4.5 of the ABAQUS Analysis User’s Manual.
(Units of F

−1

L

3

.)

2.

, the proportionality factor between pressure and velocity of the surface in the normal

direction. This quantity is the real part of the complex admittance. (Units of F

−1

L

3

T

−1

.)

3. Frequency. (Cycles/time.) Frequency dependence is active only during frequency domain

analysis in ABAQUS/Standard.

Repeat this data line as often as necessary in ABAQUS/Standard to describe the variation of the
coefficients with frequency. Only the first line entered will be used in direct-integration procedures.

Data lines to define an impedance using DATA=IMPEDANCE:

First line:

1.

, the real part of the surface impedance. (Units of F L

−3

T.)

2.

, the imaginary part of the surface impedance. (Units of F L

−3

T.)

3. Frequency. (Cycles/time.) Frequency dependence is active only during frequency domain

analysis in ABAQUS/Standard.

Repeat this data line as often as necessary in ABAQUS/Standard to describe the variation of the
coefficients with frequency. Only the first line entered will be used in direct-integration procedures.