*INITIAL CONDITIONS

9.18

*INITIAL CONDITIONS:

Specify initial conditions for the model.

This option is used to prescribe initial conditions for an analysis.

Products:

ABAQUS/Standard

ABAQUS/Explicit

ABAQUS/Aqua

Type:

Model data

Level:

Model

Reference:

“Initial conditions,” Section 27.2.1 of the ABAQUS Analysis User’s Manual

Required parameters:

TYPE

Set TYPE=ACOUSTIC STATIC PRESSURE to define initial static pressure values at acoustic
nodes for use in evaluating the cavitation status of the acoustic element nodes in ABAQUS/Explicit.

Set TYPE=CONCENTRATION to give initial normalized concentrations for a mass diffusion

analysis in ABAQUS/Standard.

Set TYPE=CONTACT to specify initial bonded contact conditions on part of the slave surface

identified by a node set in an ABAQUS/Standard analysis.

Set TYPE=FIELD to specify initial values of field variables. The VARIABLE parameter can

be used with this parameter to define the field variable number. The STEP and INC parameters can
be used in conjunction with the FILE parameter to define initial values of field variables based on
the temperature record of a results file from a previous ABAQUS/Standard heat transfer analysis.

Set TYPE=FLUID PRESSURE to give initial pressures for hydrostatic fluid filled cavities.
Set TYPE=HARDENING to prescribe initial equivalent plastic strain and, if relevant, the

initial backstress tensor or to prescribe initial volumetric compacting plastic strain for the crushable
foam model. In ABAQUS/Standard the REBAR and USER parameters can be used with this
parameter. If the USER parameter is omitted, ABAQUS/Standard assumes that the initial conditions
are defined on the data lines.

Set TYPE=INITIAL GAP to identify the elements within which tangential fluid flow exists

initially.

Set TYPE=MASS FLOW RATE to specify initial values of mass flow rates in

ABAQUS/Standard heat transfer analyses involving forced convection modeled with the
forced convection/diffusion heat transfer elements.

Set TYPE=PLASTIC STRAIN to specify initial plastic strains. The SECTION POINTS

parameter can be used with this parameter. It is assumed that the plastic strain components are
defined on each data line in the order given for the element type, as defined in Part VI, “Elements,”
of the ABAQUS Analysis User’s Manual.

9.18–1