Data lines for type = solution, rebar, Data lines for type = specific energy – ABAQUS Volume II: I–Z User Manual

Page 73

Advertising
background image

*INITIAL CONDITIONS

Subsequent lines (only needed if more than seven solution-dependent state variables exist in the model):

1. Value of eighth solution-dependent state variable.

2. Etc., up to eight solution-dependent state variables per line.

It may be necessary to leave blank data lines for some elements if any other element in the model
has more solution-dependent state variables because the total number of variables that ABAQUS
expects to read for any element is based on the maximum number of solution-dependent state
variables for all the elements in the model. These trailing initial values will be zero and will not be
used in the analysis. Values given on the data lines will be applied uniformly over the element.

Repeat this set of data lines as often as necessary to define initial values of solution-dependent state
variables for various elements or element sets.

Data lines for TYPE=SOLUTION, REBAR:

First line:

1. Element number or element set label.

2. Rebar name. If this field is left blank, the solution-dependent state variables are applied to all

rebars in these elements.

3. Value of first solution-dependent state variable.

4. Value of second solution-dependent state variable.

5. Etc., up to six solution-dependent state variables.

Subsequent lines (only needed if more than six solution-dependent state variables exist in the model):

1. Value of seventh solution-dependent state variable.

2. Etc., up to eight solution-dependent state variables per line.

It may be necessary to leave blank data lines for some elements if any other element in the model
has more solution-dependent state variables because the total number of variables that ABAQUS
expects to read for any element is based on the maximum number of solution-dependent state
variables for all the elements in the model. These trailing initial values will be zero and will not be
used in the analysis. Values given on the data lines will be applied uniformly over the element.

Repeat this set of data lines as often as necessary to define initial values of solution-dependent state
variables for various elements or element sets.

No data lines are required for TYPE=SOLUTION, USER.

Data lines for TYPE=SPECIFIC ENERGY:

First line:

1. Element number or element set label.

9.18–13

ABAQUS Version 6.1

Module: ID:

Printed on: