Required parameter, Optional parameter, Data lines to translate a substructure – ABAQUS Volume II: I–Z User Manual

Page 497

Advertising
background image

*SUBSTRUCTURE PROPERTY

18.45

*SUBSTRUCTURE PROPERTY:

Translate, rotate, and/or reflect substructures.

This option is used to define properties for a substructure. It is required for all substructures in a model.

Product:

ABAQUS/Standard

Type:

Model data

Level:

This option is not supported in a model defined in terms of an assembly of part instances.

Reference:

“Using substructures,” Section 10.1.1 of the ABAQUS Analysis User’s Manual

Required parameter:

ELSET

Set this parameter equal to the name of the element set containing the substructures for which
properties are being defined.

Optional parameter:

POSITION TOL

Set this parameter equal to the tolerance on the distance between usage level nodes and the
corresponding substructure nodes. If this parameter is omitted, the default is a tolerance of 10

−4

times the largest overall dimension within the substructure. If the parameter is given with a value
of 0.0, the position of the retained nodes is not checked.

Data lines to translate a substructure:

First (and only) line:

1. Value of the translation to be applied in the global X-direction.

2. Value of the translation to be applied in the global Y-direction.

3. Value of the translation to be applied in the global Z-direction.

Data lines to translate and/or rotate a substructure:

First line:

1. Value of the translation to be applied in the global X-direction.

2. Value of the translation to be applied in the global Y-direction.

18.45–1