*SHELL GENERAL SECTION

Optional parameter for use when the MATERIAL, the COMPOSITE, and the USER parameters
are omitted:

DEPENDENCIES

Set this parameter equal to the number of field variable dependencies included in the definition of
the scaling moduli, in addition to temperature. If this parameter is omitted, it is assumed that the
moduli are constant or depend only on temperature.

Data line if the MATERIAL parameter is included:

First (and only) line:

1. Shell thickness. This value is ignored if the NODAL THICKNESS parameter is included.

Data lines if the COMPOSITE parameter is included:

First line:

1. Layer thickness. This value is scaled if the NODAL THICKNESS parameter is included.

2. This field is not used (any value given will be ignored). It is included for compatibility with

the *SHELL SECTION option.

3. Name of the material forming this layer.

4. Orientation angle,

, (in degrees) measured positive counterclockwise relative to the

orientation definition given with the ORIENTATION parameter, where

.

If the ORIENTATION parameter is not included,

is measured relative to the default shell

local directions (see “Conventions,” Section 1.2.2 of the ABAQUS Analysis User’s Manual).

Repeat this data line as often as necessary to define the layers of the shell. The order of the laminated
shell layers with respect to the positive direction of the shell normal is defined by the order of the data
lines.

Data lines to define the shell section if the MATERIAL, the COMPOSITE, and the USER
parameters are omitted:

First line:

1. Symmetric half of the

matrix in the order

,

,

,

,

,

,

,...,

,

,...,

,...,

,...,

Repeat this data line three times. Enter 21 entries total, 8 per line.

Second line (optional):

1.

vector (

,

, ...,

).

Third line (optional):

1. Y, scaling modulus for

. The default is 1.0.

2.

, scaling modulus for

. The default is 0.0.