*INCIDENT WAVE PROPERTY

9.12

*INCIDENT WAVE PROPERTY:

Define the geometric data describing an incident

wave.

The preferred interface for defining the geometric data for an incident wave is the *INCIDENT WAVE
INTERACTION PROPERTY option used in conjunction with the *INCIDENT WAVE INTERACTION
option. The alternative interface uses the *INCIDENT WAVE PROPERTY option to define the geometric
data for incident waves. The alternative interface will be removed in a subsequent release.

Each *INCIDENT WAVE option must refer to an *INCIDENT WAVE PROPERTY definition. The

*INCIDENT WAVE PROPERTY option must be followed by the *INCIDENT WAVE FLUID PROPERTY
option, which defines the fluid properties used in the incident wave loading.

Products:

ABAQUS/Standard

ABAQUS/Explicit

Type:

Model data

Level:

Model

References:

“Acoustic loads,” Section 27.4.5 of the ABAQUS Analysis User’s Manual

*INCIDENT WAVE

*INCIDENT WAVE FLUID PROPERTY

Required parameter:

NAME

Set this parameter equal to a label that will be used to refer to the incident wave property in the

*INCIDENT WAVE option.

Optional parameter:

TYPE

Set TYPE=PLANE (default) to specify a planar incident wave.

Set TYPE=SPHERE to specify a spherical incident wave.

Data lines to define an incident wave property:

First line:

1. X-coordinate of

, the position of the incident wave standoff point.

2. Y-coordinate of

, the position of the incident wave standoff point.

3. Z-coordinate of

, the position of the incident wave standoff point.