ABAQUS Volume II: I–Z User Manual

Page 465

Advertising
background image

*STEADY STATE CRITERIA

18.32

*STEADY

STATE

CRITERIA:

Specify

steady-state

criteria

for

terminating

a

quasi-static uni-directional simulation.

This option is used to specify the norms that must be satisfied to halt a quasi-static uni-directional simulation
based on achieving a steady-state condition. It must be used in conjunction with the *STEADY STATE
DETECTION option.

Product:

ABAQUS/Explicit

Type:

History data

Level:

Step

References:

“Steady-state detection,” Section 11.8.1 of the ABAQUS Analysis User’s Manual

“Output to the output database,” Section 4.1.3 of the ABAQUS Analysis User’s Manual

*STEADY STATE DETECTION

There are no parameters associated with this option.

Data lines to define steady-state detection norms SSPEEQ and SSSPRD:

First line:

1. Norm type.

2. Norm tolerance. The default tolerance is .001.

3. Global X-coordinate of a point on the exit plane.

4. Global Y-coordinate of a point on the exit plane.

5. Global Z-coordinate of a point on the exit plane.

Repeat this data line as often as necessary. Each line defines a criterion that must be satisfied to achieve
steady state.

Data lines to define steady-state detection norms SSFORC and SSTORQ:

First line:

1. Norm type.

2. Norm tolerance. The default tolerance is .005.

3. Global X-coordinate of a point on the exit plane.

4. Global Y-coordinate of a point on the exit plane.

5. Global Z-coordinate of a point on the exit plane.

6. Rigid body reference node number.