*STEADY STATE DETECTION

18.33

*STEADY STATE DETECTION:

Specify steady-state requirements for terminating a

quasi-static uni-directional simulation.

This option is used to define the conditions that must be satisfied to determine that steady state has been
reached. It must be used in conjunction with the *STEADY STATE CRITERIA option.

Product:

ABAQUS/Explicit

Type:

History data

Level:

Step

References:

“Steady-state detection,” Section 11.8.1 of the ABAQUS Analysis User’s Manual

“Output to the output database,” Section 4.1.3 of the ABAQUS Analysis User’s Manual

*STEADY STATE CRITERIA

Required parameters:

ELSET

Set this parameter equal to the name of the element set for which this steady-state detection definition
is being applied.

SAMPLING

This parameter is used to specify the method used to sample all steady-state norms associated with
this option. See “Steady-state detection,” Section 11.8.1 of the ABAQUS Analysis User’s Manual,
for more information regarding steady-state norm definitions.

Set SAMPLING=PLANE BY PLANE to calculate the steady-state norms as each plane of

elements crosses the exit plane. This method should be used only for non-Eulerian analyses with
uniform planes of elements sequentially passing the exit plane.

Set SAMPLING=UNIFORM to calculate the steady-state norms at an interval defined by the

time required for material to flow through an element of average length. This interval is determined
at the beginning of the step and remains constant throughout the step. This method should be used
only for analyses with material flowing in and out of Eulerian boundary regions in the primary
direction.

Data line to define primary direction and cutting plane position:

First (and only) line:

1. First direction cosine of primary direction.

2. Second direction cosine of primary direction.