*VARIABLE MASS SCALING

21.1

*VARIABLE MASS SCALING:

Specify mass scaling during the step.

This option is used to specify mass scaling during the step for part or all of the model.

Product:

ABAQUS/Explicit

Type:

History data

Level:

Step

References:

“Mass scaling,” Section 11.7.1 of the ABAQUS Analysis User’s Manual

“Output,” Section 4.1.1 of the ABAQUS Analysis User’s Manual

Optional parameters:

DT

Set this parameter equal to the desired element stable time increment for the element set provided.
The mass scaling is applied according to the method specified with the TYPE parameter. If the DT
parameter is omitted, all variable mass scaling definitions from previous steps are removed, and the
scaled mass matrix from the end of the previous step is carried over to the current step.

ELSET

Set this parameter equal to the name of the element set for which this mass scaling definition is
being applied. If this parameter is omitted, the mass scaling definition will apply to all elements in
the model.

The *VARIABLE MASS SCALING option can be repeated with different ELSET definitions

to define different mass scaling for the specified element sets.

TYPE

Set TYPE=UNIFORM to scale the masses of the elements equally so that the smallest element
stable time increment of the scaled elements equals the value assigned to DT.

Set TYPE=BELOW MIN (default) to scale the masses of only the elements whose element

stable time increments are less than the value assigned to DT. The masses of these elements will be
scaled so that the element stable time increments equal the value assigned to DT.

Set TYPE=SET EQUAL DT to scale the masses of all elements so that they have the same

element stable time increment equal to the value assigned to DT.

Set TYPE=ROLLING to scale the element masses automatically for the simulation of a rolling

process. The appropriate value for the target stable time increment is determined by ABAQUS from
several parameters of the rolling process. The DT parameter will be ignored in this case.