Required parameter, Optional parameters – ABAQUS Volume II: I–Z User Manual

Page 489

Advertising
background image

*SUBSTRUCTURE GENERATE

18.41

*SUBSTRUCTURE GENERATE:

Substructure generation analysis.

This option is used to indicate that the step should be analyzed as a substructure generation step.

Product:

ABAQUS/Standard

Type:

History data

Level:

This option is not supported in a model defined in terms of an assembly of part instances.

Reference:

“Defining substructures,” Section 10.1.2 of the ABAQUS Analysis User’s Manual

Required parameter:

TYPE

Set this parameter equal to the identifier to be assigned to this substructure in a substructure library.
The identifier must be Z followed by a number that cannot exceed 9999.

Substructure identifiers must be unique within a library. If a substructure already exists in

the library with this same identifier, the analysis will terminate with an error message unless the
OVERWRITE parameter is specified.

Optional parameters:

GRAVITY LOAD

Set GRAVITY LOAD=YES to calculate the substructure’s gravity load vectors. The default is
GRAVITY LOAD=NO.

LIBRARY

Set this parameter equal to the name of the substructure library on which the substructure data will
be written. See “Input syntax rules,” Section 1.2.1 of the ABAQUS Analysis User’s Manual, for
the syntax of such library names. The default library name is jobname.

MASS MATRIX

Set MASS MATRIX=YES to calculate the substructure’s reduced mass matrix. The default is
MASS MATRIX=NO.

OVERWRITE

Include this parameter to overwrite an existing substructure with the same TYPE identifier in the
library. The default is no overwrite.

18.41–1

ABAQUS Version 6.1

Module: ID:

Printed on:

Advertising