HARDWARE DESCRIPTION

——————

AL0

It blinks when the “Duplicate MAC ID” test has not been passed.

AL1, AL2

Not used and are always off.

2.7 TECHNICAL SPECIFICATIONS

Storage temperature:

-20°... +70°C (-68...+158°F)

Operating temperature:

0°... +55°C (32...+131°F)

Such temperatures are suitable to be used with those of the drive, which they
are connected to.

2.8 INTERFACE

The board has to be installed on the regulation board so that the XO connector
of the 6KCV300DVN board is placed near the XO connector of the regulation
board, thus keeping the DeviceNet connection terminal in a downward position.

As for the mechanical connection use the kit delivered with the board.

As for the electrical connection use the 40-pole flat cable included in the kit.

As for the Bus connection use a shielded “twisted pair cable”.

The connection among the single boards is carried out via a shielded cable
as shown in the figure below:

6KCV300DVN

PE

Shield

6KCV300DVN

6KC300DVN