6KCV300DVN

7

77

———— KEYBOARD INTERFACE ———

7.7.5 CNXN status

The following states of the connections are displayed:

1.

PE - Predefined Mode Explicit connection status .

2.

PP - Predefined Mode Polled connection status .

3.

UE - UCMM Explicit connection status.

Every single state can assume following values:

·

0 = does not exist.

·

1 = Configuring.

·

2 = Waiting for ID.

·

3 = Established.

·

4 = Timed-out.

·

5 = Deferred.

The following table shows the values of the single states corresponding to
specific operating conditions

CONDITION

PE

PP

UE

Disconnected SBI card

0

0

0

1)

Connected PLC

3

3

0

1)

Disconnected PLC

3

4 or 0

0

1)

dn6010

1)

UE might have values different from zero occasionally for some seconds
from the allocation by PLC.

7.7.6 I/O CNXN status

The following states of the I/O connections are displayed:

1.

EPR Expected Packet Rate; milliseconds indicating the Timeout, set by
the Master.

2.

C Consuption Length; number of byte consumed (direction Master->Sla-
ve); set by the Master, for the board 6KCV300DVN is 8.

3.

P Produced Length; number of byte produced (direction Slave->Master)
; set by the Master, for the board 6KCV300DVN is 8.