POLLING FUNCTION

——————

4

44

4.2.6.2.3 Read Single Polling M->S configuration - Reply Error

If the reading of the single configuration of the Polling M->S is rejected, the
response is the following:

DATA TYPE

FIELD

VALUE

MEANING

Service

Code

14hex OR

80hex

Get _Attribute_Single Reply

code- Common Service.

1Fhex

Error vendor specific (see

Additional field)

<> 1Fhex

DeviceNet specific error

code (see DeviceNet

Specifications).

Additional

XX

1)

Drive specific error code.

dn4105

Byte

General

Error

1)

For error codes see chapter 6.0.

4.2.6.2.4 Read Entire Polling M->S configuration

The data frame for the reading of the total configuration of the Polling M->S is
composed as follows:

DATA TYPE

FIELD

VALUE

MEANING

Byte

Service Code

01hex

Get_Attribute_All -Common

Service.

Class ID

69hex

Polling M->S Configuration

Class Object.

Instance ID

01

Polling M->S Instance ID.

dn4210

See Note

1)

1)

Byte or Word depending on the type of allocation executed by the Master.

4.2.6.2.5 Read Entire Polling M->S configuration - Reply OK

If the entire configuration of the Polling M->S is read correctly, the response is
composed as follows:

DATA TYPE

FIELD

VALUE

MEANING

Byte

Service Code

01hex OR

80hex

Get_Attribute_All -Common

Service.

Word 0 Polling

M->S

Drive parameter index assigned

to the Polling M->S first word.

Word xx

Polling M->S

Drive parameter index assigned
to the Polling M->S xx th word.

Word 4 Polling

M->S

Drive parameter index assigned

to the Polling M->S 4th word.

dn4220

Word

XXXX

1)

1)

The format of the Drive parameter index is Low Byte - High byte.