7.7.7 DUP MAC ID test (DMC)

The 6KCV300DVN board carries out a Test to check if there is another node
with the same address (Duplicate MAC ID) in the network; if there is a
duplication of a node address, the following message shows up:

DUP. MAC ID TEST
FAILED

In addition to this information, the red LED AL0 starts blinking.

In this case the address of the 6KCV300DVN board must be changed.

If the “Duplicate MAC ID” test is positive, the following message shows up:

DUP. MAC ID TEST
PASSED

This message means that the MAC ID is correct.

During the “Duplicate MAC ID” test, the following message shows up:

DUP. MAC ID TEST
IN PROGRESS - X

X is the current DMC state.

This test takes about two seconds; if the message remains, check cables,
connections and Baud Rate. See also the paragraph “Status of Allocation” to
display the Sw Dnet status.

7.7.8 Display software version (software version)

The Software version of the 6KCV300DVN board is shown.

7.7.9 Display compatibility index (compatib. index)

The index of compatibility of the Software between the Drive and the
6KCV300DVN board is shown.