2 configuration object virtual digital output, 1 class code, 2 class attributes – GE Industrial Solutions 6KCV300DVN User Manual
Page 54: 3 instance attributes
GEI-100431
————
SETTING VIRTUAL DIGITAL I/Os
————
5
54
5.2 CONFIGURATION OBJECT VIRTUAL DIGITAL OUTPUT
For the assignment of Drive parameters to the 16 Words of the Virtual Digital
Outputs a new object with a specific identifier class is used.
The object is made as follows:
Class ID: 6Bh.
Class Attribute:
Revision
Instance Attribute:
·
ID = 1: Word for configuration first Output (direction Master ->Slave).
·
ID = 2: Word for configuration second Output (direction Master->Slave).
·
ID = x: Word for configuration Outputs (direction Master->Slave).
·
ID = 16; Word for configuration sixteenth Output (direction Master->Sla-
ve).
5.2.1 Class code
Class Code: 6Bhex
5.2.2 Class attributes
Number
Need in
implementation
Access Rule
Name DeviceNet
Data Type
Description
of Attribute
Semantics of
values
1
Optional
Get
Revision
UINT
Revision of
this object
dn345
5.2.3 Instance attributes
Number
Need in
implementation
Access Rule
Name DeviceNet
Data Type
1
X
16
dn5100
Description of Attribute
Drive parameter assigned to
the first Virtual Digital
Output
Drive parameter assigned to
the Xth Virtual Digital
Output
Drive parameter assigned to
the 16th Virtual Digital
Output
Required
Set
DGT
Out
Conf.
UINT