POLLING FUNCTION

——————

4.2.6.2 Read M->S Polling configuration

In this example is shown the writing of the configuration of the Polling M->S;
the cases of positive and wrong reading are distinguished.

4.2.6.2.1 Read Single Polling M->S configuration

The data frame for the reading of the single configuration of the Polling M->S
is composed as follows:

DATA TYPE

FIELD

VALUE

MEANING

Byte

Service Code

0Ehex

Get_Attribute_Single -

Common Service

Class ID

69hex

Polling M ->S Configuration

Class Object

Instance ID

01

Polling M ->S Instance ID

Byte

Attribute ID

XX

Polling M ->S word involved

in configuration

dn4190

See Note

1)

1)

Byte or Word depending on the type of allocation executed by the Master.

4.2.6.2.2 Read Single Polling M->S configuration - Reply OK

If the single configuration of the Polling M->S is read correctly, the response
is composed as follows:

DATA TYPE

FIELD

VALUE

MEANING

Byte

Service Code

0Ehex OR

80hex

Get_Attribute_Single Reply

code- Common Service.

Word

Word XX

Polling M->S XXXX

1)

Drive parameter index assigned

to the Polling M->S XX word.

dn4200

1)

The format of the Drive parameter index is Low Byte - High byte.