4 read entire virtual digital input configuration – GE Industrial Solutions 6KCV300DVN User Manual

Page 52

Advertising
background image

GEI-100431

————

SETTING VIRTUAL DIGITAL I/Os

————

5

52

DATA TYPE

FIELD

VALUE

MEANING

Byte

Service Code

0Ehex OR

80hex

Get_Attribute_Single Reply code-

Common Service.

Word

Word 0 Virtual

Digital Input

XXXX

1)

Drive parameter index assigned to

the Virtual Digital Input XX

word.

dn5060

1)

The format of the Drive parameter index is Low Byte - High byte.

5.1.6.2.3 Read single Virtual Digital Input configuration - Reply Error

If the reading of the single configuration of the “Virtual Digital Inputs” is
rejected, the response is the following:

DATA TYPE

FIELD

VALUE

MEANING

Service

Code

14hex OR

80hex

Get _Attribute_Single Reply

code- Common Service.

1Fhex

Error vendor specific (see

Additional field)

<> 1Fhex

DeviceNet specific error

code (see DeviceNet

Specifications).

Additional

XX

1)

Drive specific error code.

dn4105

Byte

General

Error

1)

For error codes see chapter 6.0.

5.1.6.2.4 Read entire Virtual Digital Input configuration

The data frame for the reading of the entire configuration of the “Virtual
Digital Inputs” is composed as follows:

DATA TYPE

FIELD

VALUE

MEANING

Byte

Service Code

01hex

Get_Attribute_All - Common

Service.

Class ID

6Ahex

Virtual Digital I/O

Configuration Class Object

Instance ID

01

Virtual Digital Input Instance

ID

dn5070

See Note

1)

1)

Byte or Word depending on the type of allocation executed by the Master.

5.1.6.2.5 Read entire Virtual Digital Input configuration - Reply OK

If the entire configuration of the “Virtual Digital Inputs” is read correctly, the
response is composed as follows:

Advertising