3

27

——————

DEVICENET FUNCTION

——————

6KCV300DVN

3.2.2.6.1.1 Write DGF parameter request

The data frame for writing a DGF parameter is composed as follows:

DATA TYPE

FIELD

VALUE

MEANING

Byte

Service

Code

33hex

Set DGF Parameter -

Object Specific Service.

Class ID

67hex

DGF Parameter Access

Class Object.

Instance

ID

XXXX

DGF Parameter Index in

format Low byte-High

byte.

Data Type

2)

XX

DGF specific data type

code.

N/U

00

Not used; has to be set to

zero.

XX

Low byte-Low word DGF

parameter value.

XX

High byte-Low word DGF

parameter value.

XX

Low byte-High word DGF

parameter value.

XX

High byte-High word

DGF parameter value.

dn3960ge

VALUE

See Note

1)

Byte

1) Byte or Word depending on the type of allocation executed by the Master.

2) For codes see DGF- manual.

3.2.2.6.1.2 Write DGF parameter - Reply OK

If the DGF parameter is written correctly, the response is:

DATA TYPE

FIELD

VALUE

MEANING

Byte

Service

Code

33hex OR

80hex

Set DGF Parameter

Reply code- Object

Specific Service.

Word

Result

0

Result field equal to zero

means writing correctly

executed.

dn3970ge