GE Industrial Solutions 6KCV300DVN User Manual
Page 68
GEI-100431
———— KEYBOARD INTERFACE ———
7
68
7.5 DRIVE VIRTUAL DIGITAL I/O PARAMETER ASSIGNMENT
EDITING
The flowchart illustrating Editing of Drive parameter assignments to Virtual
Digital I/O is shown below. Note that pressing Cancel at any time returns to
the previous Menu or cancels the operation in course. Refer to chapter 7.8 for
Editing.
Enter virtual digital
(Input/Output) pressed
Password enabled
or active ?
Enter password
Password OK ?
Enter parameter index
Send to the drive
Drive reply OK ?
Exit
Warning
Warning
Exit
Exit
yes
Save in E2PROM
no
no
yes
yes
no
The validity of the specified Drive parameters is checked by the Drive. If the
Drive returns with an error code, the following message will be displayed on
the keypad screen:
Par. not assign.
Err. code: XXXXh
TSB8040
The error code generated by the Drive is displayed in hexadecimal format;
error codes are listed in chapter 6.0. If parameter specification is correct, the
following message will be displayed:
ENTER OK !
TSB8050
This message automatically disappears after two seconds, or upon pressing
the Cancel key.
Refer to section 7.6.1 for messages regarding Password entry.