0 setting of virtual digital i/o, 1 object configuration virtual digital inputs, 1 class code – GE Industrial Solutions 6KCV300DVN User Manual

Page 47

Advertising
background image

6KCV300DVN

5

47

————

SETTING VIRTUAL DIGITAL I/Os

————

5.0 SETTING OF VIRTUAL DIGITAL I/O

The configuration of the Virtual Digital I/Os, may be set by keypad and stored
on E2PROM of the 6KCV300DVN board.

For the configuration of the “Virtual Digital I/Os” two new communication
objects are defined.

The setting is allowed in every status of communication and is protected by
password.

Remember that in this chapter the virtual digital inputs/outputs refer to the
Drive, it means that the Master can “write” the virtual digital inputs and
“read” the virtual digital outputs.

Default value: all at zero.

5.1 OBJECT CONFIGURATION VIRTUAL DIGITAL INPUTS

For the assignment of the Drive parameters to the 16 Words of the Virtual
Digital Inputs is used a new object with a specific class identifier.

The object is composed as follows:

Class ID: 6Ah.

Class Attribute:

Revision

Instance Attribute:

·

ID = 1: Word for configuration first Input (direction Master ->Slave).

·

ID = 2: Word for configuration second Input (direction Master->Slave).

·

ID = x: Word for configuration Inputs (direction Master->Slave).

·

ID = 16; Word for configuration sixteenth Input (direction Master->Sla-
ve).

5.1.1 Class code

Class Code: 6Ahex

Advertising