background image

Automation Command and Query Reference Manual - Control Reference

C4Level

Double

From -4.1 to 4.1 step 0.01

Range

Channel 4 trigger level control.

Description

C4Slope

Enum

Channel 4 trigger slope control.

Description

Values

Either

Negative

Positive

ExtCoupling

Enum

External Input coupling control.

Description

Values

AC

DC

HFREJ

LFREJ

ExtLevel

Double

From -0.41 to 0.41 step 0.001

Range

External trigger input level control.

Description

ExtSlope

Enum

External trigger input slope control.

Description

Values

Either

Negative

Positive

LineLevel

Double

From 0 to 1 step 0.001

Range

Control the trigger level for the Line trigger input.

Description

1-32

918501 RevA