Automation Command and Query Reference Manual - Processor Reference

CursorDisplay

Enum

Set/Query the CursorDisplay cvar. This defines whether the source trace is annotated with 'Help
Markers' generated by the measurement.

Description

Values

Detailed

Off

Simple

EYEAVGPOWER

app.Measure.Px.Operator (ParamEngine = "EyeAvgPower")

Aperture

Double

From 0 to 100 step 0.1

Range

For eye-diagram parameters which have an "aperture" setting, this defines the region over which the
eye digrams vertical information is analyzed.
It specifies the percentage of the central region of the eye (relative to 1 Unit Interval) which is used in
the analysis.

Description

Aperture

Double

EYEBER

app.Measure.Px.Operator (ParamEngine = "EyeBER")

Aperture

Double

From 0 to 100 step 0.1

Range

For eye-diagram parameters which have an "aperture" setting, this defines the region over which the
eye digrams vertical information is analyzed.
It specifies the percentage of the central region of the eye (relative to 1 Unit Interval) which is used in
the analysis.

Description

Aperture

Double

CursorDisplay

Enum