Automation Command and Query Reference Manual - Processor Reference

VerBType

Enum

Values

dualDirac

sinePDF

triangular

uniform

VerGaussian

Double

From 0 to 1 step 0.0001

Range

VerNoiseOn

Bool

LOWPASSIIR

app.Math.Fx.OperatorYSetup (Operator = "LowPassIIR")

Cutoff

Double

From 10000 to 5e+011 step 1000

Range

FilterType

Enum

Values

Butterworth

Chebyshev1

Log2BuffSize

Integer

From 10 to 17 step 1

Range

Order

Integer

From 1 to 12 step 1

Range

Ripple

Double

From 0.01 to 4 step 0.01

Range

Cutoff

Double

FilterType

Enum

Log2BuffSize

Integer

Order

Integer

Ripple

Double

Warning

String

2-36