Teledyne LeCroy WavePro Automation Command User Manual

Page 518

Advertising
background image

Automation Command and Query Reference Manual - Processor Reference

' Visual Basic Script
Set app = CreateObject("LeCroy.XStreamDSO")

' Configure F1 to filter C1
app.Math.F1.View = True
app.Math.F1.Source1 = "C1"
app.Math.F1.MathMode = "OneOperator"
app.Math.F1.Operator1 = "Filter"
app.Math.F1.Operator1Setup.FirO

Example

AutoLength

Bool

Enables/Disables/Queries status of the auto-length feature for the filter Fx.

Description

FilterKind

Enum

Sets/Queries kind of filter to use in function Fx.

Description

Values

BandPass

BandStop

Custom

Gaussian

HighPass

LowPass

RaisedCosine

RaisedRootCosine

FIRMissingPointsLocation

Enum

Values

Left

LeftRight

Right

FitAlways

Bool

LowFreqPass

Double

NumberOfTaps

Integer

PassBandRipple

Double

ReframeOutput

Bool

SampleRateText

String

StopBandAttenuation

Double

TransitionWidth

Double

2-19

918501 RevA

Advertising