Figure 525-1, Dlp-525, Page 3 of 6 – ADC Soneplex Broadband System User Manual

Page 106: Figure 525-1. version a rlx configuration switches

Advertising
background image

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-83

© 2000, ADC Telecommunications, Inc.

DLP-525

Page 3 of 6

8. Repeat entire procedure for each RLX module.

Stop! You have completed this procedure.

6262-A

SA2

SA3

SA3-1

CONFIGURATION

SWITCH PLACEMENT

= 22.5 DB
= 15 DB
= 7.5 DB
= 0 DB

OPEN

1

2

3

OPEN

1

2

3

OPEN

1

2

3

NOT USED

SPAN POWER
CLOSED = ON

OPEN = OFF

DSX LINE EQUALIZATION
OPEN, OPEN, OPEN
CLOSED, OPEN, OPEN
OPEN, CLOSED, OPEN
CLOSED, CLOSED, OPEN
OPEN. OPEN, CLOSED

= 0 TO 133 FT
= 133 TO 266 FT
= 266 TO 399 FT
= 399 TO 533 FT
= 533 TO 655 FT

NID LOOP CODE RECOGNITION
CLOSED = ENABLE
OPEN = DISABLE

TRANSMIT LINE BUILDOUT
CLOSED, CLOSED
CLOSED, OPEN
OPEN CLOSED
OPEN, OPEN

SA2

SA3

SA3-1

Figure 525-1. Version A RLX Configuration Switches