Ise, refer to, Figure 516-1, For the s – ADC Soneplex Broadband System User Manual

Page 81: Table 516-1, Dlp-516, Page 3 of 6

Advertising
background image

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-58
© 2000, ADC Telecommunications, Inc.

DLP-516

Page 3 of 6

5170-C

CONFIGURATION SWITCHES

(COMPONENT SIDE VIEW)

DEFAULT SWITCH SETTINGS : 6, 5, 4 - ON, 3, 2, 1 - OFF

6

5

4

3

2

1

ON

6

5

4

3

2

1

ON

SWITCH

6

5

4

3,2,1

FUNCTION

LOOP POWER

UNUSED

LOOP 2

LINE LENGTH 3 2 1
0 - 133 FT OFF OFF OFF
133 - 266 FT OFF OFF ON
266 - 399 FT OFF ON OFF
399 - 533 FT OFF ON ON
533 - 655 FT ON OFF OFF

POSITION

ON (ENABLED)
OFF (DISABLED)

ON (ENABLED)
OFF (DISABLED)

Figure 516-1. Version C HLXC Module Configuration Switches