ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-161

© 2000, ADC Telecommunications, Inc.

DLP-548

Page 2 of 5

Table 548-2. HLX and HRX Status Field Displays

STATUS FIELD: MODULE

DISPLAY

DESCRIPTION

DS1 Loopback

ACTIVE,
INACTIVE

A loopback is active or has been deactivated at
the HLXC, HRX, or HLXR.

DS1 LOS

YES, NO

A loss of signal has occurred at the HLXC, HRX,
or HLXR.

DS1 Line Code

AMI, B8ZS, AUTO,
N/A

See DLP-531 for descriptions of related HLX
configuration fields.

DS1 Frame Format

UNFRAMED,
Ft ONLY,
ESF,
SF, N/A
AUTO

See DLP-531 for descriptions of related HLX
configuration fields.

Loop Reversal

YES, NO, N/A

A loop reversal has occurred at the HLXC, HRX,
or HLXR.

HSKP1/HSKP2

YES, NO, N/A

Housekeeping alarms 1 and/or 2 have occurred at

the HLXC, HRX, or HLXR.

PWR1/PWR2

YES, NO, N/A

Power alarms 1 and/or 2 have occurred at the

HLXC, HRX, or HLXR.

STATUS FIELD: HDSL LOOPS

DISPLAY

DESCRIPTION

(HDSL) Start-Up IP

YES, NO, N/A

MPU5.2 software or later: no HRXs or MPU 5.1
software.

NRM, DIS, LSW

MPU 5.2 software or later: Normal, Disabled, or
Loss of Synch Word at Loop 1 or Loop 2 at the
HLXC or HLXR.

Tip-Ring (T/R) Reversal

YES, NO, N/A

SNR (Thresh) Exceeded

YES, NO, N/A

See DLP-531 for descriptions of related HLX
configuration fields.

BER (Thresh) Exceeded

YES, NO, N/A

See DLP-531 for descriptions of related HLX
configuration fields.

Pulse Attn (dB)

Range of +1 to +40

See DLP-531 for descriptions of related HLX
configuration fields.

SNR (margin dB)

Range of –10 to +30

See DLP-531 for descriptions of related HLX
configuration fields.

Advertising