Table 534-1. RLX Configuration Fields, continued

FIELD

TYPE

OPTIONS

DESCRIPTION

DEFAULT

BER Threshold

Toggle

Range of 10-3 to 10-9

The average Bit Error Ratios of both the
incoming DS1 signals are monitored by the
RLX. By monitoring BERs, the RLX is
capable of triggering a minor alarm when
any of the monitored signals degrades
below the BER threshold level.

10-7

Span Power Setting*

Toggle

UNIT SWITCH†

Defaults to the span power hardware
configuration (DIP SWITCH) setting on the
Version A RLX only.

Version A only: UNIT
SWITCH

ENABLED

Allows span power on the Version B RLX.
To activate this selection, its jumper must
be set to either ±130V or –130V as shown
in

Figure 525-2

or

Figure 525-3

.

Version B only:
ENABLED

DISABLED

Stops span power on the Version B RLX.

Pulse Equalization*

Fixed

Locked at NOT APPL.

LBO Setting*†

Toggle

UNIT SWITCH

Defaults to the hardware configuration (DIP
SWITCH) LBO setting on the Version A
RLX.

Version A only: UNIT
SWITCH

0.0 dB, 7.5 dB, 15.0
dB, or 22.5 dB

Version A only: Overrides the hardware
configuration (DIP SWITCH) setting. Sets
the LBO in decibels.

Version B only: Sets the LBO in decibels.

Version B only: 0.0 dB

Programmable
Loopback

Toggle

ENABLED

Enables response to programmable
loopback codes and overrides hardware
configuration settings.

DISABLED

DISABLED

Disables response to programmable
loopback codes and overrides hardware
configuration settings.

*Note: Unit switch settings (Pulse Equalization, Span Power, NID, and LBO) are shown on the bottom of the configuration screen.

†Note: The UNIT SWITCH option appears on screen for both RLX types, but is only functional for Version A.