ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-45

© 2000, ADC Telecommunications, Inc.

DLP-509

Page 1 of 1

RLX AND RLXIOR STATUS DISPLAY

Summary:

This procedure provides instructions for displaying the status of the RLX or

RLXIOR modules installed in the selected chassis.

Note:

The RLXIOR is displayed as “RLX” in the Craft Interface menus and screens.

Note:

Press CONTROL-A for help information about moving around and editing fields.

1. Use the arrow keys to select Display RLX Status from the Display Status menu. Press Enter

or Return. A Display RLX Status screen is shown in

Figure 509-1

.

2. Move to the Group toggle field. Select group number 1, 2, 3, 4, 5, 6, or 7.

3. Move to the Slot toggle field. Select slot number 1, 2, 3, or 4.

Reference:

TAD-106

Access Identifier

Stop! You have completed this procedure.

6180-B

RLX STATUS

Group: 1 Slot: 1

Circuit ID:

DS1 Lpbk Active: NO

Customer LOS: NO

Network LOS: NO

DS1 Line Code: AUTO-NR-B8ZS

DS1 Frame Format: AUTO-NR-ESF

DS1 BER Thresh Exceeded: NO

Press CONTROL-A For Assistance

Figure 509-1. RLX Status Screen (Typical)