Figure 548-1, Figure 548-2, Dlp-548 – ADC Soneplex Broadband System User Manual

Page 185: Page 3 of 5

Advertising
background image

ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-162
© 2000, ADC Telecommunications, Inc.

DLP-548

Page 3 of 5

HLX/HRX STATUS

Group: 1 Slot: 2 Circuit ID:

HLXC HRX1 HRX2 HLXR
=========== =========== =========== ===========
DS1 Loopback

: INACTIVE N/A N/A INACTIVE

DS1 LOS

: YES N/A N/A YES

DS1 Line Code

: AMI N/A N/A AMI

DS1 Frame Format

: N/A N/A N/A N/A

Loop Reversal

: N/A N/A N/A NO

HSKP1/HSKP2

: N/A N/A N/A NO

PWR1/PWR2

: N/A N/A N/A NO

HLXC CRP1 RRP1 CRP2 RRP2 HLXR
HDSL LP1 LP2 LP1 LP2 LP1 LP2 LP1 LP2 LP1 LP2 LP1 LP2
============= === === === === === === === === === === === ===
HDSL LP STAT: NRM NRM N/A N/A N/A N/A N/A N/A N/A N/A NRM NRM
T/R Reversal: N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A NO NO
SNR Exceeded: NO NO N/A N/A N/A N/A N/A N/A N/A N/A NO NO
BER Exceeded: NO NO N/A N/A N/A N/A N/A N/A N/A N/A NO NO
Pulse Attn : +0 +0 N/A N/A N/A N/A N/A N/A N/A N/A +0 +0
SNR margin : +26 +26 N/A N/A N/A N/A N/A N/A N/A N/A +24 +25

Press CONTROL-A For Assistance

14858-A

Note:

The SNR and PA values are only updated when the HDSL loop is active. If the HDSL loop

has never been activated, the SNR value will be set to 71, and the PA value will be set to 0.

Figure 548-1. HLX Status Screen (MPU V5.3 Without an HRX)

HLX/HRX STATUS

Group: 1 Slot: 2 Circuit ID:

HLXC HRX1 HRX2 HLXR
=========== =========== =========== ===========
DS1 Loopback

: INACTIVE INACTIVE N/A INACTIVE

DS1 LOS

: YES N/A N/A YES

DS1 Line Code

: AMI N/A N/A AMI

DS1 Frame Format

: N/A N/A N/A N/A

Loop Reversal

: N/A NO N/A NO

HSKP1/HSKP2

: N/A N/A N/A NO

PWR1/PWR2

: N/A N/A N/A NO

HLXC CRP1 RRP1 CRP2 RRP2 HLXR
HDSL LP1 LP2 LP1 LP2 LP1 LP2 LP1 LP2 LP1 LP2 LP1 LP2
============= === === === === === === === === === === === ===
HDSL LP STAT: NRM NRM NRM NRM NRM NRM N/A N/A N/A N/A NRM NRM
T/R Reversal: N/A N/A NO NO N/A N/A N/A N/A N/A N/A NO NO
SNR Exceeded: NO NO NO NO NO NO N/A N/A N/A N/A NO NO
BER Exceeded: NO NO NO NO NO NO N/A N/A N/A N/A NO NO
Pulse Attn : +0 +0 +0 +0 +0 +0 N/A N/A N/A N/A +0 +0
SNR margin : +25 +25 +24 +24 +25 +25 N/A N/A N/A N/A +24 +24

Press CONTROL-A For Assistance

14857-A

Note:

The SNR and PA values are only updated when the HDSL loop is active. If the HDSL loop

has never been activated, the SNR value will be set to 71, and the PA value will be set to 0.

Note:

Figure 548-4

provides a key to the HRX status column headings shown in this figure.

Figure 548-2. HLX/HRX Status Screen (MPU V5.3 With One HRX)