ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-295

© 2000, ADC Telecommunications, Inc.

TAP-101

Page 9 of 13

Table 101-1. Alarm Descriptions/Conditions, continued

HLXC ALARMS, AID = EQPT-LIU#

CONDITION

DESCRIPTION

BOARD FAIL

Fatal hardware or software error

COMM FAIL

MPU unable to communicate with HLXC

HLXR INCOMPATIBLE

Incompatible software versions with remote module

HRX INCOMPATIBLE

Incompatible software versions with HRX

LOOP REVERSAL

Pairs crossed at HLXR

TP/RNG REVERSAL

Tip and Ring reversed (either loop)

PRIMARY POWER

Local power fail indication (1) detected at HLXR

SECONDARY POWER

Local power fail indication (2) detected at HLXR

HLXC ALARMS, AID = T1

CONDITION

DESCRIPTION

AIS

AIS detected

LOOPBACK

Signal looped back toward network

LOF

DS1 Loss of Frame

LOS

DS1 Loss of Signal

T-BERL

DS1 BER threshold crossed (based on BPVs)

YEL

Yellow alarm (DS1) detected

HLXC ALARMS, AID = HDSL

CONDITION

DESCRIPTION

DC CONTINUITY

Loss of loop power DC continuity detected

LOF

Loss of Frame (a.k.a. HDSL Loss of Sync Word (LOSW) Failure)

RECOVERY

HDSL loop is performing start-up process

T-BERP

HDSL loop BER threshold crossed (based on HDSL CRC)

T-PA

HDSL Pulse Attenuation threshold crossed.

T-SNR

HDSL loop SNR threshold crossed

HLXC ALARMS, AID = EQPT-EXT#

CONDITION

DESCRIPTION

RMT-HSKP1

Housekeeping contact closure (1) detected at HLXR

RMT-HSKP2

Housekeeping contact closure (2) detected at HLXR

(continued)