ADCP-61-471 • Issue 4 • June 2000 • Section 2: Operation and Maintenance

2-293

© 2000, ADC Telecommunications, Inc.

TAP-101

Page 7 of 13

Table 101-1. Alarm Descriptions/Conditions

MPU ALARMS, AID = EQPT-MPU#

CONDITION

DESCRIPTION

GRP 1 MISMATCH

Invalid card type combination in group 1

GRP 2 MISMATCH

Invalid card type combination in group 2

GRP 3 MISMATCH

Invalid card type combination in group 3

GRP 4 MISMATCH

Invalid card type combination in group 4

GRP 5 MISMATCH

Invalid card type combination in group 5

GRP 6 MISMATCH

Invalid card type combination in group 6

GRP 7 MISMATCH

Invalid card type combination in group 7

POWER

Chassis power input (A or B) not connected

CGA

Carrier Group Alarm: 6 or more DS1’s in MAJOR alarm

EXTERNAL ALARMS, AID = EQPT-EXT#

CONDITION

DESCRIPTION

HSKP1*

Contact closure detected at HSKP IN, pair 1 on backplane

HSKP2*

Contact closure detected at HSKP IN, pair 2 on backplane

HSKP3*

Contact closure detected at HSKP IN, pair 3 on backplane

HSKP4*

Contact closure detected at HSKP IN, pair 4 on backplane

HSKP5*

Contact closure detected at HSKP IN, pair 5 on backplane

HSKP6*

Contact closure detected at HSKP IN, pair 6 on backplane

HSKP7*

Contact closure detected at HSKP IN, pair 7 on backplane

HSKP8*

Contact closure detected at HSKP IN, pair 8 on backplane

DS3 MUX ALARMS, AID = T3

CONDITION

DESCRIPTION

AIS

AIS (Alarm Indication Signal) detected

APS LIMIT

APS limit of 3 switches in 24 hours has been reached, APS disabled

FORCE TO WORK

Working module forced online, APS disabled

FORCE TO PROT

Protect module forced online, APS disabled

IDLE

Idle code detected

LOF

Loss of Frame

LOOPED BACK

Signal looped back toward network

LOS

Loss of Signal

YELLOW

Yellow alarm detected

* HSKP alarm names can be configured in the Shelf Housekeeping Labels screen, described in DLP-550.

(continued)